High Voltage High Efficiency Permanent Magnet Synchronous Motor

High Voltage High Efficiency Permanent Magnet Synchronous Motor

one, six-10KV high voltage asynchronous commencing permanent magnet synchronous motor,
two. Adopt high-efficiency “Magnet King” uncommon earth everlasting magnet supplies, establish air-hole magnetic area, transform electrical power into mechanical electricity output, and generate industrial loads
three.Because of to the use of rare earth high-performance long lasting magnetic materials, the institution of a working air hole magnetic area, no need to draw reactive excitation existing from the electricity source, its electrical power factor reaches earlier mentioned .96, and the effectiveness is normally two% -8% higher than the Y sequence motor, especially the effectiveness Rapidly boost as the load raises, keep large-effectiveness procedure inside of a broad load assortment of twenty five% -a hundred and twenty%, and the product enters the national suggested catalog of high-efficiency vitality-preserving motors.
4. Asynchronous commencing long term magnet synchronous motor adopts the “indiscriminate substitute” style technologies of the Y series motor. The product corresponds to the voltage degree and installation dimensions of the Y collection motor, and can be changed with “no distinction” at the rated voltage and frequency, it has the capability of self-beginning, synchronous operation and no slip.
5. In addition to the excellent higher-performance, strength-conserving and inexpensive running traits of the high-voltage and large-effectiveness everlasting magnet motor, the higher power factor enables the motor to operate under the identical load conditions.
(1). The running existing is significantly diminished
(2). The temperature increase is lowered by more than 30K, and the working daily life is prolonged.
(3). Lessen distribution community present and minimize cable temperature increase
(4). Reduction of reactive power payment capacity of enterprise distribution community
(5). The commencing torque numerous is larger than the asynchronous motor of the same power, which increases the beginning functionality of heavy load.
(6). Normal power performance attribute curve diagram
  
Fig.Typical strength effectiveness attribute curve of TYCKK sequence high voltage and large efficiency asynchronous commencing long lasting magnet synchronous motor

Application regions:
Goods are widely used in energy, metallurgy, chemical substances, developing supplies, h2o remedy, coal mines, mining, textiles, rubber, glass, petroleum, transportation, medication, papermaking, food and other industries, aiding enterprises decrease emissions, help save power, minimize usage, and environmentally friendly manufacturing.

Composition and working basic principle of energy-productive operation:
The stator structure of the large-voltage and large-performance asynchronous starting up permanent magnet synchronous motor is comparable to that of common Y sequence asynchronous motors. The company’s research and improvement group makes use of modern substantial-performance motor layout concept and layout technology to optimize the core and windings the rotor is outfitted with a higher-functionality exceptional earth “magnetic king” to enhance the squirrel cage structure, which can generate higher than common asynchronous motors at rated voltage and frequency CZPTting torque.
The exceptional earth “Magnetic King” is the world’s regarded permanent magnetic material with the optimum magnetic energy solution in the globe. It is saturated and magnetized to current a “permanent magnetic field”. After it is put in in the motor, it does not want the electricity reactive existing, the long term magnetic discipline of “Magnetic King”, and the three-phase recent of the winding to interact to create secure electromagnetic torque to push the load.
This structural feature of the long lasting magnet motor helps make the power factor higher. Below the issue of guaranteeing the same output electrical power, the present is substantially reduced, the resistance loss of the winding is lowered, there is nearly no rotor reduction throughout operation, and it exhibits important substantial efficiency and vitality saving characteristics. As the whole reduction is diminished, the temperature rise is lowered by a lot more than 30K in contrast with common asynchronous motors, and the functioning life is prolonged. This is the standard functioning theory of an asynchronous starting permanent magnet synchronous motor.
 
TYCKK sequence high voltage and large efficiency asynchronous commencing long term magnet synchronous motor
The simple series are 3-section, 6KV, 10KV, 50HZ, air-to-air cooling, security class IP54, F-course insulation, installation kind IMB3, operating system S1. It can fulfill the user’s requirements for other protection levels, cooling methods and set up forms.

 

High Voltage High Efficiency Permanent Magnet Synchronous Motor