{"id":3039,"date":"2024-05-16T03:59:29","date_gmt":"2024-05-16T03:59:29","guid":{"rendered":"https:\/\/acgearmotor.top\/china-manufacturer-110kw-12000rpm-air-compressor-permanent-magnet-motor-and-vfd-ac-3-phase-industrial-vacuum-pump-diy\/"},"modified":"2024-05-16T03:59:29","modified_gmt":"2024-05-16T03:59:29","slug":"china-manufacturer-110kw-12000rpm-air-compressor-permanent-magnet-motor-and-vfd-ac-3-phase-industrial-vacuum-pump-diy","status":"publish","type":"post","link":"https:\/\/acgearmotor.top\/es\/china-manufacturer-110kw-12000rpm-air-compressor-permanent-magnet-motor-and-vfd-ac-3-phase-industrial-vacuum-pump-diy\/","title":{"rendered":"China manufacturer 110kw 12000rpm Air Compressor Permanent Magnet Motor and VFD AC 3-Phase Industrial vacuum pump diy"},"content":{"rendered":"
\n
\n

Product Description<\/h2>\n

\n

Air Compressor Permanent Magnet Motor and VFD\u00a0 110kw 12000rpm AC 3-phase Industrial<\/strong> <\/p>\n

Product Feature<\/strong>
1.Suitable for the 12000rpm Rated Speed
2.Reserve a large margin of security
3.High power & High torque
4.High efficiency\u00a0
5.Small size\u00a0
6.Low noise low vibration
7.The autonomous patented cooling structure <\/p>\n

Specifications<\/strong>
Voltage: 380V AC\/540V DC
Rated Power: 110KW
Rated Speed:12000rpm
Isolation: H
Cooling Method: Oil Cooling
Ingress Protection:IP67(IP54 option)
Duty type: S1
Pole:4
Installation: B3,B5,B35
Max Net Weight: 105kg <\/p>\n

Above price includes VFD cost<\/b> <\/p>\n

Application:<\/b>
high speed compressor, fan, pump <\/p>\n

Customer Case\u00a0<\/b> <\/p>\n

Other motors you will be interested in<\/strong> <\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n<\/colgroup>\n\n\n\n\n\n\n\n\n
Motor type<\/strong><\/td>\nVoltage
(V AC)<\/strong><\/td>\n
Rated power
(kW)<\/strong><\/td>\n
Rated torque (N.m)<\/strong><\/td>\nRated speed
(rpm)<\/strong><\/td>\n
Efficiency
(%)<\/strong><\/td>\n
Duty type\u00a0<\/strong><\/td>\nInsulation\u00a0\u00a0<\/strong><\/td>\nIngress protection<\/strong><\/td>\nPole Number<\/strong><\/td>\nWeight
(kg)<\/strong><\/td>\n
Cooling Method<\/strong><\/td>\nposition signal<\/strong><\/td>\n<\/tr>\n
SRPM160H4XO15<\/td>\n380<\/td>\n15<\/td>\n5.96<\/td>\n24000<\/td>\n96.5<\/td>\nS1<\/td>\nH\/F<\/td>\nIP67<\/td>\n4<\/td>\n12<\/td>\nOil\u00a0<\/td>\nResolver<\/td>\n<\/tr>\n
SRPM160H4XO75<\/td>\n380<\/td>\n75<\/td>\n35.8<\/td>\n20000<\/td>\n96.5<\/td>\nS1<\/td>\nH\/F<\/td>\nIP67<\/td>\n4<\/td>\n44<\/td>\nOil\u00a0<\/td>\nResolver<\/td>\n<\/tr>\n
SRPM160H4XO90<\/td>\n380<\/td>\n90<\/td>\n43<\/td>\n20000<\/td>\n96.5<\/td>\nS1<\/td>\nH\/F<\/td>\nIP67<\/td>\n4<\/td>\n48<\/td>\nOil\u00a0<\/td>\nResolver<\/td>\n<\/tr>\n
SRPM205H4XO110<\/td>\n380<\/td>\n110<\/td>\n52.5<\/td>\n20000<\/td>\n96.5<\/td>\nS1<\/td>\nH\/F<\/td>\nIP67<\/td>\n4<\/td>\n76<\/td>\nOil\u00a0<\/td>\nResolver<\/td>\n<\/tr>\n
SRPM205H4XO160<\/td>\n380<\/td>\n160<\/td>\n76.4<\/td>\n20000<\/td>\n96.5<\/td>\nS1<\/td>\nH\/F<\/td>\nIP67<\/td>\n4<\/td>\n86<\/td>\nOil\u00a0<\/td>\nResolver<\/td>\n<\/tr>\n
SRPM205H4XO200<\/td>\n380<\/td>\n200<\/td>\n95.5<\/td>\n20000<\/td>\n96.5<\/td>\nS1<\/td>\nH\/F<\/td>\nIP67<\/td>\n4<\/td>\n95<\/td>\nOil\u00a0<\/td>\nResolver<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

FAQ
1. Can performanent magnet synchronous motor be used as generator?\u00a0<\/strong>
Yes. Permanent magnet synchronous motor \u00a0can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
\u00a0
2. Why can not directly use 3 phase ac supply voltage to start permanent magnet synchronous motor?\u00a0<\/strong>
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.\u00a0
\u00a0
3. Any special technical request on this motor’s VFD driver? And Do you have such driver?\u00a0<\/strong>
Permanent magnet synchronous motor’s driver should be vector control VFD with special inner software, such as CHINAMFG 6SE70 series, Yakawa CR5 series, ABB ACS800 series, CHINAMFG A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.\u00a0
\u00a0
4. Is there any protective measures to defend permanent magnet rotor from failure?<\/strong>\u00a0
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.\u00a0
\u00a0
5. Where is this permanent magnet synchronous motor normally used to?\u00a0<\/strong>
This permanent magnet synchronous motor is normally used to variable frequency speed situation <\/p>\n

\u00a0 \t\/* January 22, 2571 19:08:37 *\/!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(\/(.*?):(.*)$\/))&&1\t <\/p>\n

\n

\n