{"id":1478,"date":"2020-12-08T12:42:26","date_gmt":"2020-12-08T12:42:26","guid":{"rendered":"https:\/\/acgearmotor.top\/160kw-24000rpm-high-speed-permanent-magnetic-ac-motor\/"},"modified":"2020-12-08T12:42:26","modified_gmt":"2020-12-08T12:42:26","slug":"160kw-24000rpm-high-speed-permanent-magnetic-ac-motor","status":"publish","type":"post","link":"https:\/\/acgearmotor.top\/fi\/160kw-24000rpm-high-speed-permanent-magnetic-ac-motor\/","title":{"rendered":"160kw 24000rpm High Speed Permanent Magnetic AC Motor"},"content":{"rendered":"
<\/p>\n
160KW 24000RPM Large Speed Permanent Magnetic AC Motor<\/p>\n Solution Function<\/strong> Specifications<\/strong> Software<\/strong> Other motors you will be interested in<\/strong><\/p>\n FAQ \n 160KW 24000RPM Large Speed Permanent Magnetic AC Motor Solution Functionone.Appropriate for the 24000rpm higher pace2.Reserve a large margin of safety3.Substantial energy & higher torque4.Higher effectivenessfive.Tiny sizesix.Low sounds low vibrationseven.The autonomous patented cooling framework SpecificationsModel sort: SRPM160H4XO160Voltage: 380V ACRated Power: 160KWPrice Torque : seventy six.four N.mDoing work pace: 24000rpmEfficiency: ninety six.5%Duty Type: S1Isolation: H\/FH2o\/dust Proof:IP54(IP67 option)Pole […]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[2],"tags":[],"class_list":["post-1478","post","type-post","status-publish","format-standard","hentry","category-product-catalog"],"_links":{"self":[{"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/posts\/1478","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/comments?post=1478"}],"version-history":[{"count":0,"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/posts\/1478\/revisions"}],"wp:attachment":[{"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/media?parent=1478"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/categories?post=1478"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/acgearmotor.top\/fi\/wp-json\/wp\/v2\/tags?post=1478"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}
one.Appropriate for the 24000rpm higher pace
2.Reserve a large margin of safety
3.Substantial energy & higher torque
4.Higher effectiveness
five.Tiny size
six.Low sounds low vibration
seven.The autonomous patented cooling framework<\/p>\n
Model sort: SRPM160H4XO160
Voltage: 380V AC
Rated Power: 160KW
Price Torque : seventy six.four N.m
Doing work pace: 24000rpm
Efficiency: ninety six.5%
Duty Type: S1
Isolation: H\/F
H2o\/dust Proof:IP54(IP67 option)
Pole Variety: four
N Bodyweight: 86KG
Cooling Technique: Oil
Situation Signal: Resolver (optional)<\/p>\n
High-speed Compressors,Followers,Pumps<\/p>\n\n
\n Motor type<\/strong><\/td>\n Voltage
(V AC)<\/strong><\/td>\nRated power
(kW)<\/strong><\/td>\nRated torque (N.m)<\/strong><\/td>\n Rated velocity
(rpm)<\/strong><\/td>\nEffectiveness
(%)<\/strong><\/td>\nObligation type\u00a0<\/strong><\/td>\n Insulation<\/strong><\/td>\n Ingress security<\/strong><\/td>\n Pole Variety<\/strong><\/td>\n Fat
(kg)<\/strong><\/td>\nCooling Technique<\/strong><\/td>\n position signal<\/strong><\/td>\n<\/tr>\n \n SRPM160H4XO15<\/td>\n 380<\/td>\n fifteen<\/td>\n five.ninety six<\/td>\n 24000<\/td>\n 96.five<\/td>\n S1<\/td>\n H\/F<\/td>\n IP67<\/td>\n 4<\/td>\n 12<\/td>\n Oil\u00a0<\/td>\n Resolver<\/td>\n<\/tr>\n \n SRPM160H4XO75<\/td>\n 380<\/td>\n seventy five<\/td>\n 35.eight<\/td>\n 24000<\/td>\n ninety six.5<\/td>\n S1<\/td>\n H\/F<\/td>\n IP67<\/td>\n 4<\/td>\n forty four<\/td>\n Oil\u00a0<\/td>\n Resolver<\/td>\n<\/tr>\n \n SRPM160H4XO90<\/td>\n 380<\/td>\n 90<\/td>\n forty three<\/td>\n 24000<\/td>\n ninety six.five<\/td>\n S1<\/td>\n H\/F<\/td>\n IP67<\/td>\n 4<\/td>\n forty eight<\/td>\n Oil\u00a0<\/td>\n Resolver<\/td>\n<\/tr>\n \n SRPM205H4XO110<\/td>\n 380<\/td>\n one hundred ten<\/td>\n 52.five<\/td>\n 24000<\/td>\n ninety six.five<\/td>\n S1<\/td>\n H\/F<\/td>\n IP67<\/td>\n 4<\/td>\n 76<\/td>\n Oil\u00a0<\/td>\n Resolver<\/td>\n<\/tr>\n \n SRPM205H4XO160<\/td>\n 380<\/td>\n one hundred sixty<\/td>\n 76.four<\/td>\n 24000<\/td>\n 96.5<\/td>\n S1<\/td>\n H\/F<\/td>\n IP67<\/td>\n four<\/td>\n 86<\/td>\n Oil\u00a0<\/td>\n Resolver<\/td>\n<\/tr>\n \n SRPM205H4XO200<\/td>\n 380<\/td>\n two hundred<\/td>\n ninety five.five<\/td>\n 24000<\/td>\n ninety six.5<\/td>\n S1<\/td>\n H\/F<\/td>\n IP67<\/td>\n 4<\/td>\n ninety five<\/td>\n Oil\u00a0<\/td>\n Resolver<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
1. Can performanent magnet synchronous motor be used as generator?\u00a0<\/strong>
No. Permanent magnet synchronous motor is completely distinct from generator. It is only ac motor that outputs speed and torque to generate electric products, but not electrical power source.\u00a0
\u00a0
two. Why can not right use three period ac provide voltage to start off permanent magnet synchronous motor?\u00a0<\/strong>
Becuase rotor is with massive innertia, and magetic files spins so fast that static rotor has no way to spin with magetic submitted.\u00a0
\u00a0
3. Any particular complex request on this motor’s VFD driver? And Do you have such driver?\u00a0<\/strong>
Long lasting magnet synchronous motor’s driver must be vector management VFD with unique inner application, this sort of as Siemens 6SE70 series, Yakawa CR5 sequence, ABB ACS800 sequence, Mitsubishi A740 collection, B&R P84 and P74 series, and so forth.. Sure, our MH300 series VFD matches with this motor.\u00a0
\u00a0
4. Is there any protecting measures to defend permanent magnet rotor from failure?<\/strong>\u00a0
Of course, every long term magnet rotor passes corrossion resistance, consistency, large temperature demagnetization check, linear demagnetization take a look at, and so forth. Its demagnetization index is inside two%. But if operating atmosphere is severe oxiditive corrosion, kindly recommend for increased safety amount.\u00a0
\u00a0
5. Where is this long term magnet synchronous motor typically utilized to?\u00a0<\/strong>
This everlasting magnet synchronous motor is usually used to variable frequency velocity situation. <\/p>\n