{"id":1284,"date":"2020-12-01T21:52:01","date_gmt":"2020-12-01T21:52:01","guid":{"rendered":"https:\/\/acgearmotor.top\/ip67-high-ingress-protection-level-permanent-magnet-dc-motor\/"},"modified":"2020-12-01T21:52:01","modified_gmt":"2020-12-01T21:52:01","slug":"ip67-high-ingress-protection-level-permanent-magnet-dc-motor","status":"publish","type":"post","link":"https:\/\/acgearmotor.top\/ja\/ip67-high-ingress-protection-level-permanent-magnet-dc-motor\/","title":{"rendered":"IP67 High Ingress Protection Level Permanent Magnet DC Motor"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"IP67 High Ingress Protection Level Permanent Magnet DC Motor\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/motor-base-1.jpg\" alt=\"IP67 High Ingress Protection Level Permanent Magnet DC Motor\" \/><\/p>\n<p><p>                                    <strong>IP67 Substantial Ingress Security Level Everlasting Magnet DC Motor<\/strong><\/p>\n<p><strong>Item Characteristic<\/strong><\/p>\n<p>1.Permanent Magnet Motor with high speed rpm<\/p>\n<p><p>2.Motor Speed: 7500rpm<\/p>\n<p><p>three.Higher electricity &amp; higher torque<\/p>\n<p><p>4.Large efficiency, substantial price functionality<\/p>\n<p><p>five.Small size<\/p>\n<p><p>6.Reduced sounds lower vibration<\/p>\n<p><p>7.Patented cooling composition<\/p>\n<p><p>8.Simple upkeep, installation and commissioning<\/p>\n<p><p>9.For the two water \/ oil cooling options<\/p>\n<p><strong>Specs<\/strong><br \/>Product type: TZ205X15A<br \/>Voltage:115V DC<br \/>Rated electricity:15KW<br \/>Rated torque:40N.m<br \/>Peak power:30KW<br \/>Peak torque:110N.m<br \/>Highest velocity:7500rpm<br \/>Peak current:290A<br \/>Optimum efficiency:&gt;=ninety five.five<br \/>Insulation:H<br \/>Ingress protection:IP67<br \/>Excess weight:21kg<br \/>Electricity density:one.42KW\/kg<br \/>Cooling approach:Normal cooling<br \/>Position sign:Resolver (optional)<\/p>\n<p><strong>Other motors you will be intrigued in<\/strong><\/p>\n<table>\n<colgroup>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Motor sort<\/strong><\/td>\n<td><strong>Voltage<br \/>(V DC)<\/strong><\/td>\n<td><strong>Rated electrical power<br \/>(kW)<\/strong><\/td>\n<td><strong>Rated torque (N.m)<\/strong><\/td>\n<td><strong>Peak power<br \/>(kW)<\/strong><\/td>\n<td><strong>Peak torque (N.m)<\/strong><\/td>\n<td><strong>Maximum pace<br \/>(rpm)<\/strong><\/td>\n<td><strong>Peak existing (A)<\/strong><\/td>\n<td><strong>Highest effectiveness (%)<\/strong><\/td>\n<td><strong>Insulation\u00a0<\/strong><\/td>\n<td><strong>Ingress defense<\/strong><\/td>\n<td><strong>Weight<br \/>(kg)<\/strong><\/td>\n<td><strong>Electricity density<br \/>(kW\/kg)<\/strong><\/td>\n<td><strong>Cooling Approach<\/strong><\/td>\n<td><strong>\u00a0Position Signal<\/strong><\/td>\n<\/tr>\n<tr>\n<td>TZ205X15A<\/td>\n<td>a hundred and fifteen<\/td>\n<td>15<\/td>\n<td>40<\/td>\n<td>thirty<\/td>\n<td>one hundred ten<\/td>\n<td>7500<\/td>\n<td>290<\/td>\n<td>\u226595.five<\/td>\n<td>H<\/td>\n<td>IP67<\/td>\n<td>21<\/td>\n<td>one.42<\/td>\n<td>Organic cooling<\/td>\n<td>Resolver<\/td>\n<\/tr>\n<tr>\n<td>TZ205X20A<\/td>\n<td>115<\/td>\n<td>twenty<\/td>\n<td>fifty<\/td>\n<td>40<\/td>\n<td>140<\/td>\n<td>7500<\/td>\n<td>370<\/td>\n<td>\u226595.five<\/td>\n<td>H<\/td>\n<td>IP67<\/td>\n<td>28<\/td>\n<td>one.forty three<\/td>\n<td>Natural cooling<\/td>\n<td>Resolver<\/td>\n<\/tr>\n<tr>\n<td>TZ205XS50A<\/td>\n<td>380<\/td>\n<td>fifty<\/td>\n<td>one hundred ten<\/td>\n<td>one hundred<\/td>\n<td>250<\/td>\n<td>10000<\/td>\n<td>370<\/td>\n<td>\u226596.five<\/td>\n<td>H<\/td>\n<td>IP67<\/td>\n<td>forty two<\/td>\n<td>two.38<\/td>\n<td>Drinking water circulation<\/td>\n<td>Resolver<\/td>\n<\/tr>\n<tr>\n<td>TZ205XS50B<\/td>\n<td>380<\/td>\n<td>fifty<\/td>\n<td>126<\/td>\n<td>a hundred and twenty<\/td>\n<td>382<\/td>\n<td>ten thousand<\/td>\n<td>four hundred<\/td>\n<td>\u226596.five<\/td>\n<td>H<\/td>\n<td>IP67<\/td>\n<td>49<\/td>\n<td>2.45<\/td>\n<td>Water circulation<\/td>\n<td>Resolver<\/td>\n<\/tr>\n<tr>\n<td>TZ205XS50C<\/td>\n<td>330<\/td>\n<td>fifty<\/td>\n<td>a hundred thirty<\/td>\n<td>one hundred twenty<\/td>\n<td>312<\/td>\n<td>12000<\/td>\n<td>400<\/td>\n<td>\u226596.5<\/td>\n<td>H<\/td>\n<td>IP67<\/td>\n<td>49<\/td>\n<td>2.45<\/td>\n<td>Drinking water circulation<\/td>\n<td>Resolver<\/td>\n<\/tr>\n<tr>\n<td>TZ340XS60A<\/td>\n<td>340<\/td>\n<td>60<\/td>\n<td>573<\/td>\n<td>one hundred twenty<\/td>\n<td>1146<\/td>\n<td>3500<\/td>\n<td>380<\/td>\n<td>\u226596<\/td>\n<td>H<\/td>\n<td>IP67<\/td>\n<td>a hundred and eighty<\/td>\n<td>.sixty seven<\/td>\n<td>Drinking water circulation<\/td>\n<td>Resolver<\/td>\n<\/tr>\n<tr>\n<td>TZ340XS90A<\/td>\n<td>430<\/td>\n<td>90<\/td>\n<td>866<\/td>\n<td>one hundred eighty<\/td>\n<td>1732<\/td>\n<td>3500<\/td>\n<td>450<\/td>\n<td>\u226596<\/td>\n<td>H<\/td>\n<td>IP67<\/td>\n<td>270<\/td>\n<td>.66<\/td>\n<td>Drinking water circulation<\/td>\n<td>Resolver<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n<p>\n<p><img decoding=\"async\" style=\"height:auto\" title=\"IP67 High Ingress Protection Level Permanent Magnet DC Motor\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/motor-base-2.jpg\" alt=\"IP67 High Ingress Protection Level Permanent Magnet DC Motor\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>IP67 Substantial Ingress Security Level Everlasting Magnet DC Motor Item Characteristic 1.Permanent Magnet Motor with high speed rpm 2.Motor Speed: 7500rpm three.Higher electricity &amp; higher torque 4.Large efficiency, substantial price functionality five.Small size 6.Reduced sounds lower vibration 7.Patented cooling composition 8.Simple upkeep, installation and commissioning 9.For the two water \/ oil cooling options SpecsProduct type: TZ205X15AVoltage:115V DCRated electricity:15KWRated torque:40N.mPeak power:30KWPeak torque:110N.mHighest velocity:7500rpmPeak current:290AOptimum efficiency:&gt;=ninety five.fiveInsulation:HIngress protection:IP67Excess weight:21kgElectricity density:one.42KW\/kgCooling approach:Normal coolingPosition sign:Resolver (optional) Other motors you will be intrigued in Motor sort Voltage(V DC) Rated electrical power(kW) Rated torque (N.m) Peak power(kW) Peak torque (N.m) Maximum pace(rpm) Peak existing (A) Highest effectiveness (%) Insulation\u00a0 Ingress defense Weight(kg) Electricity density(kW\/kg) Cooling Approach [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[2],"tags":[],"class_list":["post-1284","post","type-post","status-publish","format-standard","hentry","category-product-catalog"],"_links":{"self":[{"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/posts\/1284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/comments?post=1284"}],"version-history":[{"count":0,"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/posts\/1284\/revisions"}],"wp:attachment":[{"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/media?parent=1284"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/categories?post=1284"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/acgearmotor.top\/ja\/wp-json\/wp\/v2\/tags?post=1284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}