{"id":1713,"date":"2020-12-17T12:25:22","date_gmt":"2020-12-17T12:25:22","guid":{"rendered":"https:\/\/acgearmotor.top\/yc-ycl-1-1kw-2hp-heavy-duty-series-single-phase-capacitor-start-asynchronous-motor\/"},"modified":"2020-12-17T12:25:22","modified_gmt":"2020-12-17T12:25:22","slug":"yc-ycl-1-1kw-2hp-heavy-duty-series-single-phase-capacitor-start-asynchronous-motor","status":"publish","type":"post","link":"https:\/\/acgearmotor.top\/th\/yc-ycl-1-1kw-2hp-heavy-duty-series-single-phase-capacitor-start-asynchronous-motor\/","title":{"rendered":"Yc Ycl 1.1kw 2HP Heavy Duty Series Single-Phase Capacitor Start Asynchronous Motor"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"Yc Ycl 1.1kw 2HP Heavy Duty Series Single-Phase Capacitor Start Asynchronous Motor\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/motor-base-1.jpg\" alt=\"Yc Ycl 1.1kw 2HP Heavy Duty Series Single-Phase Capacitor Start Asynchronous Motor\" \/><\/p>\n<p>\n<p><strong>Application\u00a0<\/strong><\/p>\n<p>YC series motors are totally enclosed (TEFC) heavy-duty one-phase induction motors.The mounting simension is fully conformed with ICE regular. When rated output is 3HP or beneath,motors are of capacitor commence ,and 4HP or previously mentioned with capacitor start off and run .<\/p>\n<p>YC collection motor are itegrated with up-to-date design ,very best quality components building, and have the attributes of nice-searching appearance exceptional efficiency,simple maintenance,They also concentrate the advantages of higher starting up torque,sleek turning ,low temperature increase,lower sounds and great overload overall performance.<\/p>\n<p>YC sequence motors are suitable for powering little type drilling\u00a0 device and h2o pumps,especially for family workshops in which only one-stage existing source is CZPT.<\/p>\n<p>\u00a0<\/p>\n<p><strong>Operating Circumstances:<\/strong><\/p>\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td>Ambient temperature<\/td>\n<td>-15\u00b0c to forty \u00b0c<\/td>\n<\/tr>\n<tr>\n<td>Altitude<\/td>\n<td>\u22641000m<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage<\/td>\n<td>\n<p>1 phase: 110V, 115V, 120V, 220V, 230V, 240V, etc<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Rated frequency<\/td>\n<td>50HZ, 60HZ, 50HZ\/60HZ<\/td>\n<\/tr>\n<tr>\n<td>Obligation<\/td>\n<td>Steady(S1)<\/td>\n<\/tr>\n<tr>\n<td>Insulation class<\/td>\n<td>Class B, Class F<\/td>\n<\/tr>\n<tr>\n<td>Protection course<\/td>\n<td>IP44, IP54, IP55<\/td>\n<\/tr>\n<tr>\n<td>Cooling strategy<\/td>\n<td>IC0141<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><p>\u00a0<\/p>\n<p><strong><strong>\u00a0CZPT Information:<\/strong><\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td rowspan=\"2\">Type<\/td>\n<td colspan=\"2\">Output<\/td>\n<td rowspan=\"2\">Present<br \/>(A)<\/td>\n<td rowspan=\"2\">Power Issue<\/td>\n<td rowspan=\"2\">Eff<br \/>(%)<\/td>\n<td rowspan=\"2\">Speed<br \/>(r\/min)<\/td>\n<td rowspan=\"2\">Tst\/Tn<\/td>\n<td rowspan=\"2\">Ist\/IN<\/td>\n<td rowspan=\"2\">Tmax\/Tn<\/td>\n<\/tr>\n<tr>\n<td>KW<\/td>\n<td>HP<\/td>\n<\/tr>\n<tr>\n<td>YC80A-two<\/td>\n<td>.37<\/td>\n<td>one\/two<\/td>\n<td>3.seven<\/td>\n<td>.73<\/td>\n<td>sixty two<\/td>\n<td>2880<\/td>\n<td>2.8<\/td>\n<td>six.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC80B-two<\/td>\n<td>.55<\/td>\n<td>3\/four<\/td>\n<td>5.3<\/td>\n<td>.73<\/td>\n<td>sixty five<\/td>\n<td>2880<\/td>\n<td>2.eight<\/td>\n<td>six.5<\/td>\n<td>one.eight<\/td>\n<\/tr>\n<tr>\n<td>YC80C-2<\/td>\n<td>.seventy five<\/td>\n<td>1<\/td>\n<td>6.three<\/td>\n<td>.seventy five<\/td>\n<td>sixty eight<\/td>\n<td>2880<\/td>\n<td>two.eight<\/td>\n<td>six.5<\/td>\n<td>one.eight<\/td>\n<\/tr>\n<tr>\n<td>YC90S-2<\/td>\n<td>one.1<\/td>\n<td>one.five<\/td>\n<td>nine.1<\/td>\n<td>.79<\/td>\n<td>71<\/td>\n<td>2880<\/td>\n<td>two.5<\/td>\n<td>7.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC90L-two<\/td>\n<td>one.five<\/td>\n<td>2<\/td>\n<td>12.1<\/td>\n<td>.84<\/td>\n<td>seventy two<\/td>\n<td>2900<\/td>\n<td>two.5<\/td>\n<td>7.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC100L-two<\/td>\n<td>two.2<\/td>\n<td>3<\/td>\n<td>seventeen.one<\/td>\n<td>.84<\/td>\n<td>74<\/td>\n<td>2900<\/td>\n<td>two.2<\/td>\n<td>7.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC112M1-2<\/td>\n<td>three<\/td>\n<td>4<\/td>\n<td>21.four<\/td>\n<td>.86<\/td>\n<td>76<\/td>\n<td>2900<\/td>\n<td>2.2<\/td>\n<td>seven.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC112M2-2<\/td>\n<td>3.7<\/td>\n<td>five<\/td>\n<td>24.8<\/td>\n<td>.86<\/td>\n<td>79<\/td>\n<td>2900<\/td>\n<td>two.2<\/td>\n<td>seven.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC80A-4<\/td>\n<td>.25<\/td>\n<td>one\/3<\/td>\n<td>3.four<\/td>\n<td>.sixty<\/td>\n<td>fifty six<\/td>\n<td>1450<\/td>\n<td>three.<\/td>\n<td>six<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC80B-four<\/td>\n<td>.37<\/td>\n<td>1\/2<\/td>\n<td>4.five<\/td>\n<td>.sixty five<\/td>\n<td>sixty<\/td>\n<td>1450<\/td>\n<td>2.8<\/td>\n<td>six<\/td>\n<td>one.eight<\/td>\n<\/tr>\n<tr>\n<td>YC80C-4<\/td>\n<td>.fifty five<\/td>\n<td>three\/4<\/td>\n<td>six.<\/td>\n<td>.sixty six<\/td>\n<td>sixty four<\/td>\n<td>1450<\/td>\n<td>two.8<\/td>\n<td>6.five<\/td>\n<td>one.8<\/td>\n<\/tr>\n<tr>\n<td>YC90S-4<\/td>\n<td>.seventy five<\/td>\n<td>1<\/td>\n<td>seven.<\/td>\n<td>.sixty eight<\/td>\n<td>67<\/td>\n<td>1450<\/td>\n<td>2.five<\/td>\n<td>six.five<\/td>\n<td>1.eight<\/td>\n<\/tr>\n<tr>\n<td>YC90L-four<\/td>\n<td>1.one<\/td>\n<td>one.five<\/td>\n<td>ten.five<\/td>\n<td>.68<\/td>\n<td>70<\/td>\n<td>1450<\/td>\n<td>two.five<\/td>\n<td>six.5<\/td>\n<td>one.eight<\/td>\n<\/tr>\n<tr>\n<td>YC100L-4<\/td>\n<td>one.five<\/td>\n<td>2<\/td>\n<td>thirteen.5<\/td>\n<td>.70<\/td>\n<td>seventy two<\/td>\n<td>1450<\/td>\n<td>2.5<\/td>\n<td>six.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC112M-4<\/td>\n<td>2.2<\/td>\n<td>3<\/td>\n<td>19.three<\/td>\n<td>.72<\/td>\n<td>72<\/td>\n<td>1450<\/td>\n<td>two.two<\/td>\n<td>six.five<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC132S1-4<\/td>\n<td>three.<\/td>\n<td>four<\/td>\n<td>twenty five.two<\/td>\n<td>.seventy three<\/td>\n<td>74<\/td>\n<td>1450<\/td>\n<td>two.1<\/td>\n<td>6.5<\/td>\n<td>one.eight<\/td>\n<\/tr>\n<tr>\n<td>YC132S2-four<\/td>\n<td>three.seven<\/td>\n<td>five<\/td>\n<td>30<\/td>\n<td>.seventy four<\/td>\n<td>75<\/td>\n<td>1450<\/td>\n<td>2.one<\/td>\n<td>six.five<\/td>\n<td>one.eight<\/td>\n<\/tr>\n<tr>\n<td>YC132M1-four<\/td>\n<td>5.5<\/td>\n<td>seven.five<\/td>\n<td>32.5<\/td>\n<td>.95<\/td>\n<td>81<\/td>\n<td>1460<\/td>\n<td>2.one<\/td>\n<td>6.five<\/td>\n<td>one.8<\/td>\n<\/tr>\n<tr>\n<td>YC132M2-4<\/td>\n<td>seven.5<\/td>\n<td>ten<\/td>\n<td>forty<\/td>\n<td>.ninety five<\/td>\n<td>eighty two<\/td>\n<td>1460<\/td>\n<td>2.<\/td>\n<td>6.5<\/td>\n<td>one.eight<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<p><strong>Punch-Testing-Workshop<\/strong><\/p>\n<p><strong><\/p>\n<p><\/strong><\/p>\n<p><\/p>\n<p>\u00a0<\/p>\n<p><strong>Package deal and Transport<\/strong><\/p>\n<p><em>Why us?\u00a0<\/em><br \/>\u00a0<\/p>\n<p><strong>1.Low MOQ:<\/strong>\u00a0It can meet up with your marketing enterprise extremely effectively.<br \/>\u00a0\u00a0<br \/><strong>2.Great Provider :<\/strong>\u00a0We handle clients as close friends,providing 24 hrs a days 7days a 7 days support assist.<\/p>\n<p>\u00a0<strong>3.Good Top quality :<\/strong>We have strict high quality manage program.Excellent popularity in the industry.<br \/>\u00a0<br \/><strong>4.<\/strong><strong>Quickly &amp;\u00a0Cheap Supply:<\/strong>\u00a0We have huge price cut from CZPTer<\/p>\n<p><em>FAQ<\/em><\/p>\n<p>Q: Do you offer OEM service?<\/p>\n<p>A: Yes\u00a0<\/p>\n<p>Q: What is your payment expression?<\/p>\n<p>A: thirty% T\/T in progress, 70% equilibrium when acquiring B\/L copy.\u00a0\u00a0Or irrevocable L\/C.<\/p>\n<p>Q: What is your guide time?<\/p>\n<p>A: About thirty times right after acquiring deposit or first L\/C.<\/p>\n<p>\u00a0<\/p>\n<p>\n<p><img decoding=\"async\" style=\"height:auto\" title=\"Yc Ycl 1.1kw 2HP Heavy Duty Series Single-Phase Capacitor Start Asynchronous Motor\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/motor-base-2.jpg\" alt=\"Yc Ycl 1.1kw 2HP Heavy Duty Series Single-Phase Capacitor Start Asynchronous Motor\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Application\u00a0 YC series motors are totally enclosed (TEFC) heavy-duty one-phase induction motors.The mounting simension is fully conformed with ICE regular. When rated output is 3HP or beneath,motors are of capacitor commence ,and 4HP or previously mentioned with capacitor start off and run . YC collection motor are itegrated with up-to-date design ,very best quality components [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[2],"tags":[],"class_list":["post-1713","post","type-post","status-publish","format-standard","hentry","category-product-catalog"],"_links":{"self":[{"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/posts\/1713","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/comments?post=1713"}],"version-history":[{"count":0,"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/posts\/1713\/revisions"}],"wp:attachment":[{"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/media?parent=1713"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/categories?post=1713"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/acgearmotor.top\/th\/wp-json\/wp\/v2\/tags?post=1713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}